Carrier Air Handler: Upflow coil installation
Upflow coil installation on a Carrier air handler: The cased coil sits directly on the furnace discharge opening. It must be level and does not need screws to the furnace.
Applies to: D5FULA upflow installs
How to fix upflow coil installation: step by step
- Set the coil on the upflow furnace discharge opening.
- Level the coil so condensate drains correctly. Do not tilt it toward the drain.
- If a wider coil sits on a narrower furnace, build a field adapter and fit it.
If the unit shows an error code, look it up: Carrier Air Handler codes
Source: Carrier D5FULA installation instructions, p. 20. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.