Carrier Air Handler: Mounting options and do-not-install locations
Mounting options and do-not-install locations on a Carrier air handler: The unit can stand, lie, or hang. Some locations are not allowed.
Applies to: Indoor air handler
How to fix mounting options and do-not-install locations: step by step
- Mount the unit on the floor, or hang it from a ceiling or wall, leaving room for wiring, piping and service.
- If installed over a finished ceiling or living space, a field-supplied secondary condensate pan may be required by code under the whole unit.
- Do not install in oil drilling or fracking areas, coastal salt-air areas, or areas with caustic gases such as near hot springs.
- Do not install in factories or places with power fluctuations, enclosed cabinets, strong electromagnetic fields, or areas storing flammable materials or gas.
- Do not install in high-humidity rooms such as bathrooms or laundry rooms.
- Nuisance sweating can occur in high humidity with low airflow.
If the unit shows an error code, look it up: Carrier Air Handler codes
Source: Carrier D5FSAAH / D5FLAAH installation manual, p. 13. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.