Updated · by Aurora Star Tech Inc.

Furnace control signal connection on a Carrier air handler: Thermostat and furnace control wiring for the coil interface (non-communicating furnace control).

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FULA

How to fix furnace control signal connection: step by step

  1. Connect R to the furnace 24 VAC output and C to the common wire.
  2. Connect OW1 to the furnace first-stage heat (W1). If the furnace has only W, connect OW1 to W and leave OW2 unconnected.
  3. Connect OW2 to second-stage heat (W2). OW2 cannot be on unless OW1 is already on.
  4. Connect OG to the furnace G terminal. If the furnace has no G, connect OG to Y or Y1.
  5. Connect OY1 to furnace Y for cooling/heat pump fan speed. For 2-speed systems, connect OY1 to Y1.
  6. Connect OY2 to furnace Y2 for high fan speed; leave OY2 unconnected if not used with OY1 as Y.
  7. Use 24 V thermostat or full communication wiring per the wiring nameplate and Fig. 27 and 28.
  8. Do not use 24V communication between the interface and outdoor unit; use RS-485 or the included controller.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Source: D5FULA installation instructions, p. 31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.