Carrier Air Handler: Flare copper pipe ends
Flare copper pipe ends on a Carrier air handler: Flare the copper line ends to the sizes in the flare nut table before connecting them to the units.
Applies to: 18K to 60K D5FUAA air handler, field copper piping
How to fix flare copper pipe ends: step by step
- Remove the PVC tape from the pipe ends only when you are ready to flare.
- Clamp the flare block on the pipe so the end sticks out past the flare form.
- Place the flaring tool on the form.
- Turn the flaring tool handle clockwise until the pipe is fully flared, using the flare dimensions in the flare nut table.
- Remove the tool and block, then check the flared end for cracks and an even flare.
If the unit shows an error code, look it up: Carrier Air Handler codes
Models
45MUAAQ18XX345MUAAQ24XX345MUAAQ30XX345MUAAQ36XX345MUAAQ48XX345MUAAQ60XX3D5FUAA
Source: D5FUAA installation instructions, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.