Carrier Air Handler: Downflow coil installation

Updated · by Aurora Star Tech Inc.

Downflow coil installation on a Carrier air handler: A field adapter goes between the coil and the furnace in downflow installs.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FULA downflow installs

How to fix downflow coil installation: step by step

  1. Set the cased coil on the supply duct opening.
  2. Place a field-built adapter, at least 4 in, on the coil casing. Taper it if one side is larger.
  3. Set the furnace on the adapter.
  4. On a 4-way multiposition furnace in downflow, break off the perforated duct flanges. Check the furnace instructions.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Source: Carrier D5FULA installation instructions, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.