Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier Air Handler: Cased coil installation on a furnace

Updated · by Aurora Star Tech Inc.

Cased coil installation on a furnace on a Carrier air handler: Cased coil is fitted to the furnace supply side with the furnace power off. Duct is reconnected and the joints are sealed.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: D5FULA cased evaporator coils on gas furnaces

How to fix cased coil installation on a furnace: step by step

  1. Turn off or disconnect power to the gas furnace and remove gas piping if needed.
  2. Remove enough supply ductwork to make room for the cased coil.
  3. Level the coil and seal the gap between coil and furnace. If the sizes do not match, fill the gap with sheet metal or similar material and seal it airtight.
  4. Reconnect the ductwork to the coil casing and seal any leaks.
  5. Reconnect furnace power, turn the furnace on and check all joints for leaks.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Handler codes

Source: Carrier D5FULA installation instructions, p. 17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977