Viessmann Boiler: Heating circuit numbering (BUS ID 1/2)
Heating circuit numbering (BUS ID 1/2) on a Viessmann boiler: Heating circuits are numbered in sequence starting at 01. Never give two circuits the same number. When replacing a controller, enter the exact same heating circuit numbers as the old one. Sensor type (1 kOhm or 5 kOhm) is chosen during programming and system selection.
Applies to: Versatronik 200 system control, start-up settings
How to fix heating circuit numbering (bus id 1/2): step by step
- Number heating circuits in sequence starting at 01.
- Check that no heating circuit number is used twice on the bus.
- On a replacement controller, enter the same heating circuit numbers as the unit it replaces.
- Set the sensor type (1 kOhm or 5 kOhm) to match the system selection made during programming.
If the unit shows an error code, look it up: Viessmann Boiler codes
More commissioning tips for boiler
Source: Versatronik 200 installation and operating manual, p. 120. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.