Updated · by Aurora Star Tech Inc.

Termination clearances from meters and appliances on a Rheem furnace: Keep the vent terminal at least 4 ft horizontally from electric meters, gas meters, regulators and relief equipment. Keep the furnace combustion air inlet at least 3 ft from the vent of any other gas or fuel appliance or clothes dryer, except for multi-venting.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All venting

How to fix termination clearances from meters and appliances: step by step

  1. Measure horizontal distance from the vent terminal to meters, regulators and relief equipment.
  2. Measure distance from the combustion air inlet to nearby appliance vents and dryer vents.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Rheem Furnace codes

Models

96V

(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100

96MDV

96MDV06096MDV07096MDV08596MDV100

More other tips for furnace

Source: 96V Series installation instructions, p. 51. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.