Rheem Furnace: Gas pressure regulator and purging
Gas pressure regulator and purging on a Rheem furnace: A regulator may be needed in the supply line. Its outlet must not exceed the maximum supply pressure on the rating plate. Industrial regulators are not allowed. Gas piping must be purged to a safe location per NFGC section 8.3.
Applies to: Gas supply pressure and purging
How to fix gas pressure regulator and purging: step by step
- Confirm the regulator will not deliver more than the maximum supply pressure on the rating plate.
- Do not use an industrial-type gas regulator.
- Purge the gas piping following local codes and NFGC section 8.3 so no explosive mixture can build up.
- Only connect to gas from a commercial utility or commercial fuel provider.
If the unit shows an error code, look it up: Rheem Furnace codes
Models
(-)96V060(-)96V070(-)96V085(-)96V10096VA06096VA07096VA08596VA100
More commissioning tips for furnace
Source: 96V series installation instructions, p. 69. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.