York TM9V and M9V are 96 percent efficient, two-stage furnaces with a variable speed blower. This page follows a normal heating cycle and explains the flashing lights you may see on the control board.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the York furnace works: Furnace heating cycle

What this is. York TM9V and M9V are 96 percent efficient, two-stage furnaces with a variable speed blower. This page follows a normal heating cycle and explains the flashing lights you may see on the control board.

What happens, in order. When the thermostat asks for heat (with the fan on Auto), the inducer starts and the pressure switch must close to show enough air for combustion. The igniter warms for 17 seconds, then the gas valve opens and the flame sensor takes over. If flame is detected, the blower starts 30 seconds after the gas valve opens, at the speed chosen for heating. When the thermostat is satisfied, the gas valve closes, the vent motor runs 15 seconds to clear the fumes and the blower keeps going for the blower off delay, 120 seconds from the factory (60, 90 or 180 seconds are the other choices).

Overheat protection. If the main limit switch opens because the furnace is too hot, the furnace runs the blower and inducer to cool down. Open for over 5 minutes puts it into a hard lockout, shown by 11 red flashes. If the limit opens five times in one call, you get 4 red flashes and a one-hour wait.

Reading the light. A slow green flash is normal standby, and a slow amber flash means a call for heat. Red flash counts point to a specific problem.

What is normal. A short delay before warm air, a fan that continues after the flame is out and a gently flashing light.

Safe checks. Replace the filter, open all vents and clear the outdoor pipes.

When to call a technician. Repeated red flashes mean it's time to call Aurora Star Tech, and if you smell gas, leave and call from outside.

Key times at a glance

WhatHow long or how much
Ignitor warm-up17 s
Blower on delay30 s after gas valve opens
Vent motor post-purge15 s
Blower off delay60, 90, 120 (factory) or 180 s
Normal flame currentabout 3.7 uA
Low flame warning1.5 uA

Applies to: TM9V and M9V 96% two-stage variable speed furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the York furnace

What is the Furnace heating cycle on a York furnace?

York TM9V and M9V are 96 percent efficient, two-stage furnaces with a variable speed blower. This page follows a normal heating cycle and explains the flashing lights you may see on the control board.

Is it normal for my York furnace to do this?

A short delay before warm air, a fan that continues after the flame is out and a gently flashing light.

Who can service my York furnace near me?

Aurora Star Tech Inc. repairs and services York furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977