Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane heat pump: Heat pump demand defrost

Updated · by Aurora Star Tech Inc.

In cold weather a heat pump's outdoor coil collects frost, and a Trane 5TWR7 (XR or XV ComfortSeek) clears it with a demand defrost, which means it only defrosts when the system decides it needs to rather than on a fixed clock. This page explains how that decision is made.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Trane heat pump works: Heat pump demand defrost

What this is. In cold weather a heat pump's outdoor coil collects frost, and a Trane 5TWR7 (XR or XV ComfortSeek) clears it with a demand defrost, which means it only defrosts when the system decides it needs to rather than on a fixed clock. This page explains how that decision is made.

What happens, in order. Demand defrost is allowed only when the outdoor temperature is 50 °F or below and the unit has been heating for the required time. The control reads two sensors, one for the outdoor air and one on the coil, and works out the temperature gap between them. When that gap grows past a limit, which adjusts itself to the outdoor temperature, the control concludes frost has built up and starts a defrost. The coil sensor is also used to end the defrost once the coil is warm. With a communicating Trane thermostat, the defrost is reported to it and the higher stage of heat is called automatically so your home stays comfortable. The LED display on the outdoor board shows 7 as its first digit while defrosting.

What is normal. Steam rising from the outdoor unit, water running off it, a swoosh when the system changes direction, and cooler air from the vents for a few minutes.

Safe checks. Keep snow, ice and leaves away from the outdoor unit and leave clear space around it. Confirm the thermostat is set to Heat and the filter is clean.

Technician note. A technician can force a test defrost by holding a button on the board for more than 5 seconds, and can change the end temperature if needed.

When to call a technician. If ice stays thick for hours, the system defrosts constantly or the home will not warm up, contact Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Defrost enabledoutdoor temp at or below 50 F
Forced defrost button holdover 5 s

Applies to: 5TTR7 and 5TWR7 heat pumps

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Trane heat pump

What is the Heat pump demand defrost on a Trane heat pump?

In cold weather a heat pump's outdoor coil collects frost, and a Trane 5TWR7 (XR or XV ComfortSeek) clears it with a demand defrost, which means it only defrosts when the system decides it needs to rather than on a fixed clock. This page explains how that decision is made.

Is it normal for my Trane heat pump to do this?

Steam rising from the outdoor unit, water running off it, a swoosh when the system changes direction, and cooler air from the vents for a few minutes.

Who can service my Trane heat pump near me?

Aurora Star Tech Inc. repairs and services Trane heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977