Trane furnace: Second-stage gas heating (S8X2 only)

Updated · by Aurora Star Tech Inc.

The Trane S8X2 is a two-stage furnace. It uses a lower, gentler flame most of the time and adds a stronger second stage when the house needs more heat. This page explains how the second stage joins in and what happens if it cannot.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Trane furnace works: Second-stage gas heating (S8X2 only)

What this is. The Trane S8X2 is a two-stage furnace. It uses a lower, gentler flame most of the time and adds a stronger second stage when the house needs more heat. This page explains how the second stage joins in and what happens if it cannot.

What happens, in order. Second stage never runs on its own, because first stage must already be running. When the thermostat asks for more heat, the display shows Ht2 and then Xt2. The control checks the second-stage pressure switch, which proves airflow, is open, then runs the inducer on high speed. The second-stage gas valve then opens and the blower speeds up to its second-stage heating speed. When the extra demand is met, the second-stage valve closes and the blower slows back to first-stage speed. When the main call ends, the gas valve closes, the inducer clears the fumes and the blower finishes its off time.

If second stage will not prove. The control gives the pressure switch 45 seconds to close. If it does not, it declares a second-stage pressure switch open error and the furnace keeps heating on first stage only, so you still get warmth. It waits 10 minutes and tries again. After three failed tries in the same call, it stays on first stage until the thermostat call for second stage ends.

What is normal. A blower that gets louder when more heat is called for, and a display that changes between Xt, Ht2 and Xt2.

Safe checks. Replace the filter and clear outdoor vent pipes of snow and nests.

When to call a technician. If the house heats slowly and the error repeats, Aurora Star Tech can inspect your furnace.

Key times at a glance

WhatHow long or how much
Pressure switch 2 prove time45 s
Retry wait after PS2 failure10 min
Attempts per call3

Applies to: S8X2 two-stage furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Trane furnace

What is the Second-stage gas heating (S8X2 only) on a Trane furnace?

The Trane S8X2 is a two-stage furnace. It uses a lower, gentler flame most of the time and adds a stronger second stage when the house needs more heat. This page explains how the second stage joins in and what happens if it cannot.

Is it normal for my Trane furnace to do this?

A blower that gets louder when more heat is called for, and a display that changes between Xt, Ht2 and Xt2.

Who can service my Trane furnace near me?

Aurora Star Tech Inc. repairs and services Trane furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.