Trane furnace: Cooling and heat pump calls on S8 furnace control
Trane S8 furnaces also run your air conditioner or heat pump fan. The furnace blower moves the air even though the cooling happens outdoors. This page covers what the furnace does during a cooling or heat pump call.
How the Trane furnace works: Cooling and heat pump calls on S8 furnace control
What this is. Trane S8 furnaces also run your air conditioner or heat pump fan. The furnace blower moves the air even though the cooling happens outdoors. This page covers what the furnace does during a cooling or heat pump call.
What happens, in order. When the thermostat asks for cooling, it signals both the outdoor unit and the furnace blower. The blower ramps up to cooling airflow, and the display shows CP1 on the S8B1 and S8X1, or CL1 on the S8X2. If more cooling is needed, a second stage signal makes the outdoor unit step up and the blower speed up, and the display changes to CP2 or CL2. When the thermostat is satisfied the outdoor unit stops and the blower stops, unless the installer has set a cooling off delay. The display then returns to IDL.
Heat pump systems. On an S8X2 paired with a heat pump, the installer must set it up correctly, otherwise the display shows CL1 instead of HP1. This is a setup detail, not a danger.
Accessories. An electronic air cleaner switches on about 2 seconds after the blower and a humidifier about 1 second after.
What is normal. A quiet gradual fan start, two different fan speeds, and letters like CP1, CL1 or HP1 on the furnace display while the outdoor unit works.
Safe checks. Replace the filter, keep the supply and return vents open, set the thermostat to Cool, and keep the outdoor unit clear of leaves and debris.
When to call a technician. Weak airflow, a display that stays on one code, or no cooling after these checks is a reason to call Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| EAC relay delay | about 2 s after blower starts |
| HUM relay delay | about 1 s after blower starts |
Applies to: S8B1, S8X1 and S8X2 furnaces
Error codes linked to this step
Trane code CP1Trane code CP2Trane code CL1Trane code CL2Trane code HP1Trane code HP2Trane code IdL
Questions about the Trane furnace
What is the Cooling and heat pump calls on S8 furnace control on a Trane furnace?
Trane S8 furnaces also run your air conditioner or heat pump fan. The furnace blower moves the air even though the cooling happens outdoors. This page covers what the furnace does during a cooling or heat pump call.
Is it normal for my Trane furnace to do this?
A quiet gradual fan start, two different fan speeds, and letters like CP1, CL1 or HP1 on the furnace display while the outdoor unit works.
Who can service my Trane furnace near me?
Aurora Star Tech Inc. repairs and services Trane furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.