Rinnai air handler: Cooling call, single-stage thermostat
The Rinnai Canadian hydronic air handler, in its heat pump and air conditioner versions, also provides cooling through your ducts. Here is how a single-stage cooling call runs.
How the Rinnai air handler works: Cooling call, single-stage thermostat
What this is. The Rinnai Canadian hydronic air handler, in its heat pump and air conditioner versions, also provides cooling through your ducts. Here is how a single-stage cooling call runs.
What happens, in order. When the thermostat calls for cooling, the blower relay closes and the indoor blower starts. At the same time, the signal that starts your outdoor unit goes out, so the outdoor unit's contactor pulls in and the compressor runs. On a heat pump, the reversing valve is also set to the cooling position, depending on the outdoor unit. When the house is cool enough, the call ends, the outdoor unit stops, and the blower keeps running for an off delay of 90 seconds by default before it stops.
Why the blower lingers. That extra moment moves the last of the chilled air from the coil into your rooms.
What is normal. The blower starting right as the outdoor unit does, cool air arriving within a few minutes, and the blower running about a minute and a half after the outdoor unit stops.
Safe checks. Set the thermostat to Cool, below room temperature. Replace a dirty filter, make sure vents are open, check the breakers for both the air handler and outdoor unit, and keep the outdoor unit clear of leaves, grass and snow.
When to call a technician. If the blower runs but the air stays warm, the outdoor unit does not start, or you see water around the air handler, call Aurora Star Tech for a service visit.
Key times at a glance
| What | How long or how much |
|---|---|
| Blower off delay (default) | 90 s |
Applies to: Rinnai Canadian hydronic air handler (heat pump and A/C versions)
Questions about the Rinnai air handler
What is the Cooling call, single-stage thermostat on a Rinnai air handler?
The Rinnai Canadian hydronic air handler, in its heat pump and air conditioner versions, also provides cooling through your ducts. Here is how a single-stage cooling call runs.
Is it normal for my Rinnai air handler to do this?
The blower starting right as the outdoor unit does, cool air arriving within a few minutes, and the blower running about a minute and a half after the outdoor unit stops.
Who can service my Rinnai air handler near me?
Aurora Star Tech Inc. repairs and services Rinnai air handlers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.