The Rheem Nature Air RGRM two-stage furnace lights on high fire for the most reliable start, then drops to a gentler flame. This page describes that routine.
How the Rheem furnace works: Two-stage heat call, high-fire light-off and staging
What this is. The Rheem Nature Air RGRM two-stage furnace lights on high fire for the most reliable start, then drops to a gentler flame. This page describes that routine.
What happens, in order. When the thermostat calls for heat, the furnace runs a self-check and confirms the airflow switch is open. The inducer fan starts on high until the low airflow switch closes, within 60 seconds. After a 30-second pre-purge the spark igniter fires and the high-fire gas valve opens. A remote flame sensor must prove the flame. Once the flame is proven, the inducer and gas valve drop to low fire right away, and the main blower starts 20 seconds later at low heat speed. With a single-stage thermostat, the furnace moves to high heat after a timer of 5 or 12 minutes.
If the flame does not catch. The furnace tries up to four times, then goes into a one-hour soft lockout. Cutting power for 5 to 10 seconds at the thermostat or unit switch resets it. If the flame is lost mid-cycle, the valve closes, the inducer finishes its post-purge, and the cycle restarts. Five flame losses in one call cause a lockout.
What is normal. A louder first few seconds on high fire, followed by quieter running. The status light on the board blinks codes, such as 1, 2, 3, 4 or 6 blinks.
Safe checks. Replace a dirty filter, check the thermostat, breaker and furnace switch, and clear the outside vents.
When to call a technician. Repeated lockouts or blinking codes mean it is time for service. If you smell gas, leave the home and call from outside. Aurora Star Tech can help.
Key times at a glance
| What | How long or how much |
|---|---|
| Pre-purge | 30 s |
| Pressure switch proving | 60 s max |
| Blower on delay | 20 s after flame |
| Post-purge | 10 s |
| Ignition attempts | 4 |
| Lockout | 1 hour |
| Single-stage low-to-high timer (P7) | 5 or 12 min |
Applies to: Rheem Nature Air RGRM-04 MAES
Questions about the Rheem furnace
What is the Two-stage heat call, high-fire light-off and staging on a Rheem furnace?
The Rheem Nature Air RGRM two-stage furnace lights on high fire for the most reliable start, then drops to a gentler flame. This page describes that routine.
Is it normal for my Rheem furnace to do this?
A louder first few seconds on high fire, followed by quieter running. The status light on the board blinks codes, such as 1, 2, 3, 4 or 6 blinks.
Who can service my Rheem furnace near me?
Aurora Star Tech Inc. repairs and services Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.