Updated · by Aurora Star Tech Inc.

If the burners in your Rheem 96V or 96MDV furnace do not light, or the flame is not detected, the furnace has a defined retry routine. This page explains it so a failed first try does not worry you.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Rheem furnace works: Retry sequence when burners do not light or flame is not sensed

What this is. If the burners in your Rheem 96V or 96MDV furnace do not light, or the flame is not detected, the furnace has a defined retry routine. This page explains it so a failed first try does not worry you.

What happens, in order. On each heat call, the control checks that both pressure switches are open and starts a high-stage inducer pre-purge of 30 seconds. The gas valve then opens for an 8-second ignition trial. If the burners do not light, or the flame is not sensed, the control runs another ignition sequence. It will try up to four times in total. If all four fail, the furnace enters a lockout lasting one hour, and then tries again by itself.

What is normal. Hearing the fan, the click of the igniter and a pause, then a second attempt. One retry on a cold morning is nothing unusual. The furnace simply wants proof of flame before it continues.

What is not normal. Four attempts in a row, a lockout that repeats, or a furnace that goes cold for an hour at a time.

Safe checks. Replace a dirty filter, check the thermostat and breaker, make sure the furnace door is closed, and clear snow or nests from the outdoor vent pipes. One power reset is fine.

When to call a technician. If it locks out more than once. If you smell gas, leave the house and call from outside. Aurora Star Tech can find out why the flame is not catching.

Key times at a glance

WhatHow long or how much
Ignition attempts before lockoutup to 4
Lockout after failed attempts1 hour

Applies to: 96V and 96MDV furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Rheem furnace

What is the Retry sequence when burners do not light or flame is not sensed on a Rheem furnace?

If the burners in your Rheem 96V or 96MDV furnace do not light, or the flame is not detected, the furnace has a defined retry routine. This page explains it so a failed first try does not worry you.

Is it normal for my Rheem furnace to do this?

Hearing the fan, the click of the igniter and a pause, then a second attempt. One retry on a cold morning is nothing unusual. The furnace simply wants proof of flame before it continues.

Who can service my Rheem furnace near me?

Aurora Star Tech Inc. repairs and services Rheem furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.