Proflame gas fireplace: Proflame IPI/CPI pilot ignition and flame proving

Updated · by Aurora Star Tech Inc.

Many Proflame fireplaces, including the 584 DFC and GT systems, light their pilot electronically instead of keeping it burning. This page explains the lighting and flame-proving steps.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Proflame gas fireplace works: Proflame IPI/CPI pilot ignition and flame proving

What this is. Many Proflame fireplaces, including the 584 DFC and GT systems, light their pilot electronically instead of keeping it burning. This page explains the lighting and flame-proving steps.

What happens, in order. When the remote or switch calls for flame, the control board sparks at the pilot hood and opens the pilot valve. The pilot lights, and its flame must reach a sense electrode, which proves the pilot is burning. Only then does the board open the main valve, with a brief boost of about 2 seconds that settles to a lower steady level. The main burner lights from the pilot and adjusts its height through an electronic valve or a manual HI/LO valve. If no flame is proven, the board locks out and has to be reset using the unlock sequence in the control's own instructions. With the pilot switch set to continuous pilot, the pilot stays lit after the OFF command, while the intermittent setting lets it go out.

What is normal. Clicking sparks for a few seconds, a brief pause before the main flame, and a pilot that stays lit in continuous mode.

Safe checks. Replace the batteries in the remote and the receiver, confirm any wall switch is on and keep the glass and vent clear. Spark that keeps clicking even with the pilot lit points to a sensor or board fault.

When to call. A lockout, a fireplace that will not light, or any gas smell (leave and call from outside) is a call to Aurora Star Tech.

Key times at a glance

WhatHow long or how much
EV2 voltage after flame provenAbout 5 V DC for 2 s, then 0.6 V DC
DFC battery supply4.4-6.4 V DC (cells above 1.1 V each)
DFC AC/DC adapter supply6.7-7.3 V DC
DFC from fan control module6.0-6.4 V DC

Applies to: Proflame 880/885/886 gas valve with 584 DFC and GT remote systems

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Proflame gas fireplace

What is the Proflame IPI/CPI pilot ignition and flame proving on a Proflame gas fireplace?

Many Proflame fireplaces, including the 584 DFC and GT systems, light their pilot electronically instead of keeping it burning. This page explains the lighting and flame-proving steps.

Is it normal for my Proflame gas fireplace to do this?

Clicking sparks for a few seconds, a brief pause before the main flame, and a pilot that stays lit in continuous mode.

Who can service my Proflame gas fireplace near me?

Aurora Star Tech Inc. repairs and services Proflame gas fireplaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977