Updated · by Aurora Star Tech Inc.

Midea, Carrier and Viessmann multi-zone heat pumps (the DLCMRBH and DLCMHBH outdoor units, including the Vitocal 200-S) must regularly melt frost from their outdoor coil. This page explains how the unit decides it is time.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Midea heat pump works: Multi-zone defrost entry and exit

What this is. Midea, Carrier and Viessmann multi-zone heat pumps (the DLCMRBH and DLCMHBH outdoor units, including the Vitocal 200-S) must regularly melt frost from their outdoor coil. This page explains how the unit decides it is time.

What happens, in order. After the compressor has settled into running, the unit notes the lowest coil temperature between minutes 10 and 15 and treats it as a reference. It then watches for any of four situations: 29 minutes of total heating with a falling coil temperature, 35 minutes with a slightly different threshold, 40 minutes with a very cold coil lasting 3 minutes, or 120 minutes with a cold coil. Any of these starts a defrost.

During defrost. The four-way valve (the part that reverses the flow) and the fans follow a set defrost routine. Defrost ends when the coil warms past its quit temperature, after 10 minutes at most, or if the mode changes or the unit is turned off. The system then returns to normal heating. After a stop, the valve waits until the compressor has been off for 2 minutes to close.

What is normal. Steam from the outdoor unit, a pause in warm air indoors, a whoosh as the valve moves, and water dripping from the outdoor unit.

Safe checks. Keep snow, ice and debris clear around the outdoor unit and check that the remote or controller is set to Heat. Clean washable filters on each indoor unit.

When to call a technician. If heavy ice persists, defrost seems to repeat constantly, or rooms will not warm up, contact Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Check window for T30minute 10 to 15
Run time conditions29, 35, 40 or 120 min
Max defrost time10 min
Four-way valve closes after heat stopsafter 2 min compressor off

Applies to: Midea / Carrier / Viessmann DLCMRBH and DLCMHBH multi-zone outdoor units (Vitocal 200-S)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Midea heat pump

What is the Multi-zone defrost entry and exit on a Midea heat pump?

Midea, Carrier and Viessmann multi-zone heat pumps (the DLCMRBH and DLCMHBH outdoor units, including the Vitocal 200-S) must regularly melt frost from their outdoor coil. This page explains how the unit decides it is time.

Is it normal for my Midea heat pump to do this?

Steam from the outdoor unit, a pause in warm air indoors, a whoosh as the valve moves, and water dripping from the outdoor unit.

Who can service my Midea heat pump near me?

Aurora Star Tech Inc. repairs and services Midea heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.