Midea furnace: Refrigerant leak sensor response (A2L coil)
When a Midea A2L 96 percent furnace is paired with an air conditioning coil that uses A2L refrigerant, a small sensor monitors the air for refrigerant. This page explains what the furnace does if the sensor detects a problem.
How the Midea furnace works: Refrigerant leak sensor response (A2L coil)
What this is. When a Midea A2L 96 percent furnace is paired with an air conditioning coil that uses A2L refrigerant, a small sensor monitors the air for refrigerant. This page explains what the furnace does if the sensor detects a problem.
What happens, in order. If the sensor finds refrigerant above its alarm limit, the furnace cuts the cooling signal so the air conditioner stops. The furnace blower keeps running to move air through the space until the level drops to a safe amount. A small light on the control board flashes green twice to show this.
Other light patterns. One green flash means communication with the sensor was lost for two minutes, and cooling is stopped. Three flashes mean the sensor is connected but the board setting for it has not been turned on, which is a technician's setup task. Four flashes mean the sensor has expired or failed, cooling is stopped, and a new sensor is needed.
What is normal. None of these flashes should appear in everyday running. If cooling suddenly stops and the blower alone is running, this protection may be the reason.
Safe checks. Do not open the furnace or touch the sensor. If you hear or smell anything unusual, ventilate by opening windows and doors, and keep flames and sparks away. Do not switch the system off at the breaker unless a technician asks you to, since the blower is helping to clear the air.
When to call a technician. Any time the cooling stops with the blower running, or a light on the board is flashing, call Aurora Star Tech for a service visit. A sensor warning always needs a professional.
Applies to: Midea A2L 96 percent gas furnace paired with an A2L coil
Questions about the Midea furnace
What is the Refrigerant leak sensor response (A2L coil) on a Midea furnace?
When a Midea A2L 96 percent furnace is paired with an air conditioning coil that uses A2L refrigerant, a small sensor monitors the air for refrigerant. This page explains what the furnace does if the sensor detects a problem.
Is it normal for my Midea furnace to do this?
None of these flashes should appear in everyday running. If cooling suddenly stops and the blower alone is running, this protection may be the reason.
Who can service my Midea furnace near me?
Aurora Star Tech Inc. repairs and services Midea furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.