Updated · by Aurora Star Tech Inc.

When it is very cold, or the house needs more heat, a Midea A2L 96 percent two-stage furnace (BGH96M) runs its high stage. This page follows a call that asks for both stages of heat from the start.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Midea furnace works: High fire heat call (W1 + W2)

What this is. When it is very cold, or the house needs more heat, a Midea A2L 96 percent two-stage furnace (BGH96M) runs its high stage. This page follows a call that asks for both stages of heat from the start.

What happens, in order. The thermostat asks for heat and the inducer fan starts on high speed. After about 15 seconds the airflow safety switch closes. The inducer drops to low speed, the igniter warms for about 17 seconds, the gas valve opens and the burners light. The igniter turns off 3 seconds after the valve opens. Five seconds later the furnace steps up to the high stage, and the main blower starts about 30 seconds after that, so warm air reaches the vents at full output.

When the call ends. The inducer keeps running for 15 seconds after the thermostat is satisfied. The blower then runs at high speed for another 30 seconds, followed by a fan-off delay, normally 180 seconds, that squeezes the remaining heat out of the furnace and into your home.

What is normal. Roughly a minute before warm air, louder airflow on the high stage, and a blower that continues for several minutes after the burners go out. The fan-off delay can be adjusted by a technician if you would like more or less afterwards.

Safe checks. Replace a dirty filter, open closed vents, confirm the thermostat is on Heat and set higher than room temperature, and clear the outside vent pipes. If needed, switch the furnace power off for ten seconds and on again once.

When to call a technician. An E3 code, a furnace that never reaches the high stage, or a lack of heat means it is time for service. Aurora Star Tech can help.

Key times at a glance

WhatHow long or how much
Inducer high / switch proving15 s
Igniter preheat17 s
Delay to high stage5 s
Blower on delay30 s
Inducer stop delay after call ends15 s
Blower high speed after call ends30 s
Fan off delay (default)180 s

Applies to: Midea A2L 96 percent gas furnace

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Midea furnace

What is the High fire heat call (W1 + W2) on a Midea furnace?

When it is very cold, or the house needs more heat, a Midea A2L 96 percent two-stage furnace (BGH96M) runs its high stage. This page follows a call that asks for both stages of heat from the start.

Is it normal for my Midea furnace to do this?

Roughly a minute before warm air, louder airflow on the high stage, and a blower that continues for several minutes after the burners go out. The fan-off delay can be adjusted by a technician if you would like more or less afterwards.

Who can service my Midea furnace near me?

Aurora Star Tech Inc. repairs and services Midea furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.