Lennox heat pump: Heat pump first-stage heating
In winter, your Lennox ML14KP1 or EL16KP1 heat pump pulls warmth out of the outdoor air and sends it indoors. This page describes how a normal first-stage heating call runs and why the unit sometimes seems to ignore small safety signals at the start.
How the Lennox heat pump works: Heat pump first-stage heating
What this is. In winter, your Lennox ML14KP1 or EL16KP1 heat pump pulls warmth out of the outdoor air and sends it indoors. This page describes how a normal first-stage heating call runs and why the unit sometimes seems to ignore small safety signals at the start.
What happens, in order. With the thermostat set to Heat, the reversing valve stays in its resting position. When the thermostat calls for heat, a contactor closes and the compressor and outdoor fan start. While the outdoor coil is below about 37 °F, the control keeps adding up the heating run time as "frost time", which is how it later decides a defrost is due. When the house is warm enough, the call ends and the compressor and fan stop right away.
Freezing rain. If the low pressure switch trips twice in a row during heating, the control starts a defrost cycle, a response aimed at freezing-rain conditions.
Built-in patience. The low pressure switch is ignored for 90 seconds after the compressor starts, during defrost and for 90 seconds afterward. When it is below 15 °F outside, it is ignored for the first 10 minutes of compressor running. A fault must repeat five times before the unit locks out.
What is normal. Cooler air than from a furnace, frost on the outdoor coil, and a short pause as the unit switches to defrost and back.
Safe checks. Keep snow and ice cleared from around the outdoor unit, make sure the thermostat is on Heat, and replace a dirty filter. Do not chip ice off the coil.
When to call a technician. Repeated shutdowns, heavy ice that stays on the unit, or no warm air at all call for a visit from Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Low pressure switch ignore after start | 90 s |
| Low pressure ignore below 15 F | 10 min |
| Strikes to lockout per fault | 5 |
Applies to: ML14KP1 and EL16KP1 heat pumps
Questions about the Lennox heat pump
What is the Heat pump first-stage heating on a Lennox heat pump?
In winter, your Lennox ML14KP1 or EL16KP1 heat pump pulls warmth out of the outdoor air and sends it indoors. This page describes how a normal first-stage heating call runs and why the unit sometimes seems to ignore small safety signals at the start.
Is it normal for my Lennox heat pump to do this?
Cooler air than from a furnace, frost on the outdoor coil, and a short pause as the unit switches to defrost and back.
Who can service my Lennox heat pump near me?
Aurora Star Tech Inc. repairs and services Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.