Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox heat pump: Demand defrost cycle

Updated · by Aurora Star Tech Inc.

A Lennox ML14KP1 or EL16KP1 heat pump in winter collects frost on its outdoor coil. It does not defrost on a simple clock. It watches conditions and starts a defrost only when it figures frost has built up.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Lennox heat pump works: Demand defrost cycle

What this is. A Lennox ML14KP1 or EL16KP1 heat pump in winter collects frost on its outdoor coil. It does not defrost on a simple clock. It watches conditions and starts a defrost only when it figures frost has built up.

What happens, in order. The control tracks the outside air temperature, the coil temperature and how long the unit has been heating. Whenever the coil is below about 37 °F, heating time counts toward a frost target, which starts at 90 minutes. When the target is reached, defrost begins. If a factory jumper is in place, the compressor first pauses for 30 seconds. The unit then reverses direction, stops the outdoor fan and calls on the backup heat so the house does not go cold. Defrost ends when the coil warms to its set finish temperature, after 14 minutes, or if the thermostat call ends. The compressor pauses again for 30 seconds on the way out.

Self-adjusting. After each defrost, the control adds or subtracts up to 30 minutes from the next frost target, depending on how long the last defrost took. If it is below 10 °F outside, the target is set to 360 minutes, since there is little moisture in very cold air.

What is normal. Steam rising from the outdoor unit, a quiet outdoor fan, a whoosh as direction changes, water draining away, and the backup heat running for a few minutes.

Safe checks. Keep snow and leaves away from the outdoor unit, keep the thermostat on Heat and the filter clean.

When to call a technician. If ice builds up and stays, defrost runs constantly, or sensor fault lights show on the board, book a visit with Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Initial frost accumulation target90 min
Accumulation adjustmentplus or minus 30 min
Cold climate accumulation below 10 F360 min
Maximum defrost length14 min
Termination temperature choices50, 70, 90, 100 F (factory 50 F, 90 F if shunt missing)
Nominal defrost time shunt P360, 100, 140 (default), 165 s
Compressor off at defrost entry and exit30 s with DELAY jumper (shipped on)

Applies to: ML14KP1 and EL16KP1 heat pumps

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Lennox heat pump

What is the Demand defrost cycle on a Lennox heat pump?

A Lennox ML14KP1 or EL16KP1 heat pump in winter collects frost on its outdoor coil. It does not defrost on a simple clock. It watches conditions and starts a defrost only when it figures frost has built up.

Is it normal for my Lennox heat pump to do this?

Steam rising from the outdoor unit, a quiet outdoor fan, a whoosh as direction changes, water draining away, and the backup heat running for a few minutes.

Who can service my Lennox heat pump near me?

Aurora Star Tech Inc. repairs and services Lennox heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service