Lennox furnace: Two-stage variable speed cooling call
When your thermostat asks for cooling, a Lennox SL280UHV or SL280UHNV furnace does not only start the outdoor unit. It also controls the indoor blower in two steps, one gentle and one strong, to match how hard the air conditioner is working.
How the Lennox furnace works: Two-stage variable speed cooling call
What this is. When your thermostat asks for cooling, a Lennox SL280UHV or SL280UHNV furnace does not only start the outdoor unit. It also controls the indoor blower in two steps, one gentle and one strong, to match how hard the air conditioner is working.
What happens, in order. The thermostat calls for first-stage cooling. The furnace control first checks that the air conditioner has been off long enough. Once that timer is done, the outdoor unit's first stage starts, running the compressor and outdoor fan. Two seconds later the indoor blower starts in low cooling mode.
If the house needs more. When the thermostat asks for second-stage cooling, the second stage of the outdoor unit switches on and the blower moves up to high cooling speed. The control will ignore a second-stage request if first stage is not already running, so it always builds up in order. When second stage is satisfied, the blower drops back to low. When first stage is satisfied, the outdoor unit stops and the blower slows down along a gradual ramp-down, whose shape a technician chooses during installation.
What is normal. Several minutes of waiting after a quick off-and-on at the thermostat, a blower that eases up and down in speed instead of switching abruptly.
Safe checks. Make sure the thermostat is on Cool and set below room temperature, the breakers for both the furnace and outdoor unit are on, the filter is clean, and the outdoor unit is clear of leaves, grass and snow.
When to call a technician. If the blower runs but the air stays warm, the outdoor unit never starts, or the system turns on and off repeatedly, Aurora Star Tech can diagnose it.
Key times at a glance
| What | How long or how much |
|---|---|
| Blower on delay | 2 s |
Applies to: SL280UHV, SL280UHNV
Questions about the Lennox furnace
What is the Two-stage variable speed cooling call on a Lennox furnace?
When your thermostat asks for cooling, a Lennox SL280UHV or SL280UHNV furnace does not only start the outdoor unit. It also controls the indoor blower in two steps, one gentle and one strong, to match how hard the air conditioner is working.
Is it normal for my Lennox furnace to do this?
Several minutes of waiting after a quick off-and-on at the thermostat, a blower that eases up and down in speed instead of switching abruptly.
Who can service my Lennox furnace near me?
Aurora Star Tech Inc. repairs and services Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.