Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox furnace: Two-stage furnace heating with single-stage thermostat

Updated · by Aurora Star Tech Inc.

Lennox EL296UHV, SL280UHV, SL280UHNV and SL297UHNV furnaces are two-stage, but not every home has a two-stage thermostat. This page explains what the furnace does when it is paired with a simple single-stage thermostat.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Lennox furnace works: Two-stage furnace heating with single-stage thermostat

What this is. Lennox EL296UHV, SL280UHV, SL280UHNV and SL297UHNV furnaces are two-stage, but not every home has a two-stage thermostat. This page explains what the furnace does when it is paired with a simple single-stage thermostat.

What happens, in order. The installer sets the furnace for a single-stage thermostat. Every cycle starts the usual gentle way: a self-check, a low-speed inducer fan, a 15-second purge, a 20-second igniter warm-up and low-fire ignition. The blower starts on low heat speed after its 30-second delay. At the same moment, the furnace starts its own timer, because the thermostat cannot ask for more. If the call is still active when that timer ends, which is 7 minutes from the factory or 12 minutes if the installer chose it, the furnace steps up to high fire and the blower goes to high speed. When the call ends, the gas closes, the inducer runs 5 more seconds and the blower runs on at low speed for 60, 90, 120 or 180 seconds, depending on the setting (90 is the factory choice).

What is normal. Quieter heat for the first several minutes, a louder step-up on colder days when the house is slow to warm, and a blower that continues after the flame is out.

Safe checks. Replace the filter, keep vents and returns open and check that the thermostat is set to Heat and the breaker is on. A single power reset is reasonable.

When to call. If the furnace never steps up on a cold day, shuts off early, or a fault light flashes repeatedly. If you smell gas, go outside and call from there. Aurora Star Tech services Lennox furnaces across Vaughan, Toronto and the GTA.

Key times at a glance

WhatHow long or how much
Second-stage delay7 min (factory) or 12 min, dip switch 2
Pre-purge15 s
Ignitor warm-up20 s
Post-purge5 s
Blower off delay60, 90 (factory), 120 or 180 s

Applies to: Two-stage variable-speed Lennox furnaces with dip switch 1 ON

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Lennox furnace

What is the Two-stage furnace heating with single-stage thermostat on a Lennox furnace?

Lennox EL296UHV, SL280UHV, SL280UHNV and SL297UHNV furnaces are two-stage, but not every home has a two-stage thermostat. This page explains what the furnace does when it is paired with a simple single-stage thermostat.

Is it normal for my Lennox furnace to do this?

Quieter heat for the first several minutes, a louder step-up on colder days when the house is slow to warm, and a blower that continues after the flame is out.

Who can service my Lennox furnace near me?

Aurora Star Tech Inc. repairs and services Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977