Lennox furnace: Continuous fan with heat or cool calls
Many homeowners leave the thermostat fan on ON so the air in the house keeps circulating. This page explains how a Lennox EL195UHNE or ML180UHEK furnace handles that, and what changes when a heating or cooling call arrives.
How the Lennox furnace works: Continuous fan with heat or cool calls
What this is. Many homeowners leave the thermostat fan on ON so the air in the house keeps circulating. This page explains how a Lennox EL195UHNE or ML180UHEK furnace handles that, and what changes when a heating or cooling call arrives.
What happens, in order. With the fan on ON, the thermostat tells the furnace to run the blower at a low fan speed, and any connected electronic air cleaner is powered at the same time. If a call for heat arrives, the blower holds its fan speed until the furnace has completed its 30-second heat delay, then switches to heating speed. The air cleaner and humidifier connections stay powered. If cooling is called instead, the blower moves to cooling speed, and the air cleaner stays on. When the heating or cooling call ends, the humidifier connection drops after the inducer fan finishes its 5-second post-purge. After the usual blower off-delay, the blower settles back to fan speed, and the air cleaner remains on.
What is normal. A steady, gentle airflow all day, a change in fan sound when heating or cooling begins, and slightly cooler or warmer air in the duct between cycles.
Safe checks. Continuous fan makes filters clog sooner, so check and replace the filter more often. Make sure the thermostat is set as you want it, vents are open and the breaker is on. You can switch the fan back to AUTO at any time.
When to call. If the fan will not run, runs only with heat or cooling, or makes unusual noises, contact Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Heat speed switch delay | 30 s |
| Inducer post-purge | 5 s |
Applies to: EL195UHNE, ML180UHEK
Questions about the Lennox furnace
What is the Continuous fan with heat or cool calls on a Lennox furnace?
Many homeowners leave the thermostat fan on ON so the air in the house keeps circulating. This page explains how a Lennox EL195UHNE or ML180UHEK furnace handles that, and what changes when a heating or cooling call arrives.
Is it normal for my Lennox furnace to do this?
A steady, gentle airflow all day, a change in fan sound when heating or cooling begins, and slightly cooler or warmer air in the duct between cycles.
Who can service my Lennox furnace near me?
Aurora Star Tech Inc. repairs and services Lennox furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.