KeepRite furnace: Two-stage 95% furnace: low/high heat, staging and blower delays

Updated · by Aurora Star Tech Inc.

The KeepRite 9MXT is a two-stage furnace. It has a gentle low-fire setting for mild days and a stronger high-fire setting for cold ones. This page explains how it picks between them and how its blower is timed.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the KeepRite furnace works: Two-stage 95% furnace: low/high heat, staging and blower delays

What this is. The KeepRite 9MXT is a two-stage furnace. It has a gentle low-fire setting for mild days and a stronger high-fire setting for cold ones. This page explains how it picks between them and how its blower is timed.

What happens, in order. With a simple single-stage thermostat, the furnace begins every cycle on low and moves up to high after 12 minutes if the house still wants heat. With a two-stage thermostat, the thermostat chooses: low heat for the first call, high heat if the second call comes. On low, the blower starts 45 seconds after the gas valve opens. On high, it starts after 25 seconds. When stepping up, the inducer speeds up, a high-fire safety switch confirms airflow, the high gas valve opens, and the blower shifts to its high speed about 5 seconds later. If that high-fire safety does not confirm within 2 minutes of ignition, the furnace stays on low; if it still does not, it shuts the gas off and starts another cycle if heat is still wanted. Stepping back down only happens with a two-stage thermostat. When heat is satisfied, the gas closes, the inducer runs 15 seconds more, and the blower runs on for a delay of 2 minutes as it ships (a technician can pick 90 to 180 seconds).

What is normal. Quieter, longer cycles on low; a change in fan sound when it steps up; and a blower that coasts after the burners stop.

Safe checks. Clean the filter, keep supply vents open and check the thermostat mode.

When to call. If the furnace never reaches high heat in the cold, short-cycles or shows a flashing light, book Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Low-heat blower-on delay45 s
High-heat blower-on delay25 s
Low to high blower change5 s
Single-stage thermostat low-heat time12 min
Max time on low heat waiting for high pressure switch2 min
Inducer post-purge15 s
Heat-off delay options90 / 120 / 150 / 180 s
Heat-off delay factory120 s

Applies to: KeepRite / ICP (F-G)9MXT two-stage 95% furnace (KeepRite G9MXT)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the KeepRite furnace

What is the Two-stage 95% furnace: low/high heat, staging and blower delays on a KeepRite furnace?

The KeepRite 9MXT is a two-stage furnace. It has a gentle low-fire setting for mild days and a stronger high-fire setting for cold ones. This page explains how it picks between them and how its blower is timed.

Is it normal for my KeepRite furnace to do this?

Quieter, longer cycles on low; a change in fan sound when it steps up; and a blower that coasts after the burners stop.

Who can service my KeepRite furnace near me?

Aurora Star Tech Inc. repairs and services KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.