KeepRite furnace: Single- and two-stage 95% furnace: ignition sequence and retries
KeepRite 95% efficiency furnaces in the 9MXE (single-stage) and 9MXT (two-stage) families light their burners with a hot surface igniter, a small glowing element. This page explains the start-up routine and what happens if the flame does not catch the first time.
How the KeepRite furnace works: Single- and two-stage 95% furnace: ignition sequence and retries
What this is. KeepRite 95% efficiency furnaces in the 9MXE (single-stage) and 9MXT (two-stage) families light their burners with a hot surface igniter, a small glowing element. This page explains the start-up routine and what happens if the flame does not catch the first time.
What happens, in order. When the thermostat asks for heat, the control does a quick self-check and starts the inducer fan, a fan that pulls air through (on the two-stage model it begins at high speed). Once airflow is confirmed, it clears the chamber for 15 seconds, then the igniter warms for 17 seconds. The gas valve opens, and five seconds later the control looks for flame during a 2-second proving window. When flame is confirmed, the two-stage model slows its inducer to low speed and the blower countdown begins.
If the flame does not catch. The gas valve closes and the furnace tries the whole routine again, up to four tries in total. After the fourth failure it locks out. The lockout clears itself after 3 hours, or sooner if power to the furnace is switched off and on once. If the control ever sees flame when there should be none, it blocks gas heating and keeps the inducer running until the flame is gone.
What is normal. A short wait with no heat after the thermostat clicks, humming, clicking and an occasional second try.
Safe checks. Replace a dirty filter, close the furnace door, confirm the thermostat is in Heat and the breaker is on, and clear snow or nests from outdoor vent pipes. One power reset is fine.
When to call. Repeated lockouts, a flashing light on the furnace, or any gas smell, in which case leave the house and call from outside. Aurora Star Tech can help.
Key times at a glance
| What | How long or how much |
|---|---|
| Prepurge | 15 s |
| Igniter warm-up | 17 s |
| Flame proving | 2 s (starts 5 s after gas valve opens) |
| Ignition trials | 4 total |
| Lockout auto-reset | 3 hours |
Applies to: KeepRite / ICP (F-G)9MXE single-stage 95% furnace (KeepRite G9MXE); KeepRite / ICP (F-G)9MXT two-stage 95% furnace (KeepRite G9MXT)
Questions about the KeepRite furnace
What is the Single- and two-stage 95% furnace: ignition sequence and retries on a KeepRite furnace?
KeepRite 95% efficiency furnaces in the 9MXE (single-stage) and 9MXT (two-stage) families light their burners with a hot surface igniter, a small glowing element. This page explains the start-up routine and what happens if the flame does not catch the first time.
Is it normal for my KeepRite furnace to do this?
A short wait with no heat after the thermostat clicks, humming, clicking and an occasional second try.
Who can service my KeepRite furnace near me?
Aurora Star Tech Inc. repairs and services KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.