KeepRite furnace: Furnace blower with outdoor A/C: cooling, dehumidify and continuous fan
When a KeepRite 9MXE, 9MXT or 9MAE furnace is paired with an outdoor air conditioner, its blower also moves your cool air. This page covers cooling, dehumidify and continuous fan operation.
How the KeepRite furnace works: Furnace blower with outdoor A/C: cooling, dehumidify and continuous fan
What this is. When a KeepRite 9MXE, 9MXT or 9MAE furnace is paired with an outdoor air conditioner, its blower also moves your cool air. This page covers cooling, dehumidify and continuous fan operation.
What happens, in order. On a call for cooling, the thermostat starts the outdoor unit and the furnace blower together at cooling speed. With a two-speed system, a first-stage call runs low cool and a second-stage call runs high cool. When the thermostat is satisfied, the outdoor unit stops and the blower runs 90 seconds more to push out the last cool air; a technician can shorten that to 5 seconds. If you have a humidity-sensing thermostat, the furnace can slow the blower for up to 10 minutes at a time during high cool, then return to normal, repeating this pattern so the coil stays colder and removes more moisture (the 9MAE instead lowers airflow to 86 percent). If that humidity signal stays inactive for 48 hours, the furnace goes back to ordinary thermostat control. With the thermostat fan set to ON, the blower runs continuously at fan speed. It pauses during the igniter warm-up and start of a heat call, then returns on heat speed, and after cooling ends it finishes the 90-second delay before going back to fan speed.
What is normal. Blower speed that changes, air that feels cooler or quieter in humid weather, and the fan running after the outdoor unit stops.
Safe checks. Replace the filter, keep vents open, keep the outdoor unit clear of debris, and check thermostat settings.
When to call. If air stays warm, the blower never stops or ice forms on indoor pipes, call Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Cooling blower-off delay | 90 s (5 s with DHUM jumper) |
| Dehumidify blower step-down | max 10 min |
| Blower-off after G opens | 5 s |
| DHUM timeout | 48 hours |
Applies to: KeepRite / ICP (F-G)9MXE single-stage 95% furnace (KeepRite G9MXE); KeepRite / ICP (F-G)9MXT two-stage 95% furnace (KeepRite G9MXT); ICP (F-G)9MAE modulating 95% furnace
Questions about the KeepRite furnace
What is the Furnace blower with outdoor A/C: cooling, dehumidify and continuous fan on a KeepRite furnace?
When a KeepRite 9MXE, 9MXT or 9MAE furnace is paired with an outdoor air conditioner, its blower also moves your cool air. This page covers cooling, dehumidify and continuous fan operation.
Is it normal for my KeepRite furnace to do this?
Blower speed that changes, air that feels cooler or quieter in humid weather, and the fan running after the outdoor unit stops.
Who can service my KeepRite furnace near me?
Aurora Star Tech Inc. repairs and services KeepRite furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.