KeepRite air conditioner: Split A/C: cooling cycle with standard thermostat or communicating control
KeepRite C4A3, H4A3, T4A3 and CXA6 air conditioners cool a home by sending a signal from the thermostat to the outdoor unit and the indoor blower. This page explains a normal cooling cycle and the short waits built in to protect the equipment.
How the KeepRite air conditioner works: Split A/C: cooling cycle with standard thermostat or communicating control
What this is. KeepRite C4A3, H4A3, T4A3 and CXA6 air conditioners cool a home by sending a signal from the thermostat to the outdoor unit and the indoor blower. This page explains a normal cooling cycle and the short waits built in to protect the equipment.
What happens, in order. On a call for cooling, the thermostat sends two signals: one starts the outdoor fan and compressor, the other starts the indoor blower, which begins on high speed. When the thermostat is satisfied, both signals drop and everything stops. If your indoor unit has a time-delay relay, the blower runs 90 seconds longer to move the last of the cold air into the house. With a communicating wall control, the outdoor board adds a 5-minute start delay, which is a common reason the outdoor unit seems to take its time. On a plain 2-wire hookup, that delay is only 10 seconds. After a brown-out, where the power sags briefly, the system waits 5 minutes before restarting. If the outdoor temperature is 100 degrees Fahrenheit or hotter, the outdoor fan keeps running 1 minute after the compressor stops. The control returns to standby 2 minutes after its last communication.
What is normal. No cool air for a few minutes after you turn the system on, the indoor fan continuing for a minute and a half after cooling stops, and a pause after any power flicker.
Safe checks. Replace the filter, keep vents open, clear weeds and debris at least two feet from the outdoor unit and check the breaker.
When to call. If the outdoor fan never starts after ten minutes, the air is warm, or a code appears, contact Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Start delay (communicating) | 5 min |
| Start delay (2-wire) | 10 s |
| Brown-out recycle delay | 5 min |
| Indoor blower run-on (with TDR) | 90 s |
| Fan run-on at 100 F+ outdoor | 1 min |
| Return to standby after last communication | 2 min |
Applies to: KeepRite / ICP C4A3, H4A3, T4A3, CXA6 R-410A split air conditioners
Error codes linked to this step
Questions about the KeepRite air conditioner
What is the Split A/C: cooling cycle with standard thermostat or communicating control on a KeepRite air conditioner?
KeepRite C4A3, H4A3, T4A3 and CXA6 air conditioners cool a home by sending a signal from the thermostat to the outdoor unit and the indoor blower. This page explains a normal cooling cycle and the short waits built in to protect the equipment.
Is it normal for my KeepRite air conditioner to do this?
No cool air for a few minutes after you turn the system on, the indoor fan continuing for a minute and a half after cooling stops, and a pause after any power flicker.
Who can service my KeepRite air conditioner near me?
Aurora Star Tech Inc. repairs and services KeepRite air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.