Updated · by Aurora Star Tech Inc.

In winter, your ICP N4H3 heat pump brings warmth in from outdoor air, and when that is not enough for the day, electric backup heaters inside the indoor unit join in. This page shows how that handoff works.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the ICP heat pump works: Heat pump: heating cycle with supplemental heat

What this is. In winter, your ICP N4H3 heat pump brings warmth in from outdoor air, and when that is not enough for the day, electric backup heaters inside the indoor unit join in. This page shows how that handoff works.

What happens, in order. On a heat call, the thermostat starts the outdoor fan and compressor and the indoor blower. It does not send the signal that shifts the reversing valve, so the valve stays in its heating position. If the room keeps losing temperature, the second-stage thermostat signal turns on the first bank of electric heat. If a second bank is installed, it can be added as well. Below a temperature chosen by the installer for an outdoor thermostat, the second bank comes on regardless. When the thermostat is satisfied, the compressor, blower and heaters all shut off together.

What is normal. Air from vents that feels warm but not hot compared with a gas furnace, longer run times in cold weather, and extra warmth when the backup heat joins in. The outdoor fan also stops during defrost, which is a separate cycle.

Safe checks. Confirm the thermostat is set to Heat and above room temperature, replace a dirty filter, keep the outdoor unit clear of snow and ice, and make sure breakers are on. If the thermostat has a manual backup setting, use it only as you were shown.

When to call. If the house cannot warm up, the backup heat seems to run constantly in mild weather, or the outdoor unit is silent while the blower is running. A visit from Aurora Star Tech can sort out which part is not pulling its weight.

Applies to: ICP N4H3 heat pump

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the ICP heat pump

What is the Heat pump: heating cycle with supplemental heat on a ICP heat pump?

In winter, your ICP N4H3 heat pump brings warmth in from outdoor air, and when that is not enough for the day, electric backup heaters inside the indoor unit join in. This page shows how that handoff works.

Is it normal for my ICP heat pump to do this?

Air from vents that feels warm but not hot compared with a gas furnace, longer run times in cold weather, and extra warmth when the backup heat joins in. The outdoor fan also stops during defrost, which is a separate cycle.

Who can service my ICP heat pump near me?

Aurora Star Tech Inc. repairs and services ICP heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.