Updated · by Aurora Star Tech Inc.

An ICP N4H3 heat pump collects frost on its outdoor coil in winter. A small control board runs a timed defrost to melt it. This page explains the timer and the steps of a normal defrost.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the ICP heat pump works: Heat pump: defrost board interval and defrost timers

What this is. An ICP N4H3 heat pump collects frost on its outdoor coil in winter. A small control board runs a timed defrost to melt it. This page explains the timer and the steps of a normal defrost.

What happens, in order. The board lets defrost start only after a set interval of 30, 60 or 90 minutes of heating, with 90 minutes being the factory choice. The interval counts only while the heat pump is running and the coil is cold enough, about 32 degrees Fahrenheit. When the time is up, the unit changes to something like cooling mode: the outdoor fan stops and electric backup heat comes on to keep your air warm. A separate 10-minute safety timer runs during defrost. Defrost ends when the coil warms to about 65 degrees Fahrenheit or when that 10 minutes runs out. Then the unit switches back to heating, the outdoor fan restarts and the backup heat turns off.

What is normal. Steam rising from the outdoor unit, dripping water, an outdoor fan that pauses, a click or whoosh when it switches, and slightly cooler air indoors for a few minutes. The test routine on the board is for technicians only.

Safe checks. Keep snow, ice and debris away from the outdoor unit, with a couple of feet of clearance. Check that your filter is clean and the thermostat is in Heat mode.

When to call. Thick ice that stays for hours, a unit that seems stuck in defrost, or no heat at all. Aurora Star Tech can test the defrost controls and sensors.

Key times at a glance

WhatHow long or how much
Interval options30 / 60 / 90 min
Interval factory90 min
Defrost timer10 min fixed
Defrost startabout 32 F coil
Defrost endabout 65 F coil
Reversing valve shift on speed-up1 to 21 s

Applies to: ICP N4H3 heat pump

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the ICP heat pump

What is the Heat pump: defrost board interval and defrost timers on a ICP heat pump?

An ICP N4H3 heat pump collects frost on its outdoor coil in winter. A small control board runs a timed defrost to melt it. This page explains the timer and the steps of a normal defrost.

Is it normal for my ICP heat pump to do this?

Steam rising from the outdoor unit, dripping water, an outdoor fan that pauses, a click or whoosh when it switches, and slightly cooler air indoors for a few minutes. The test routine on the board is for technicians only.

Who can service my ICP heat pump near me?

Aurora Star Tech Inc. repairs and services ICP heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977