HTP boiler: Outdoor reset and warm weather shutoff

Updated · by Aurora Star Tech Inc.

Outdoor reset is a clever way for the HTP Elite EL boiler to save fuel. Instead of heating its water to the same high temperature all winter, it uses a sensor outside your house to work out how hot the water really needs to be.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the HTP boiler works: Outdoor reset and warm weather shutoff

What this is. Outdoor reset is a clever way for the HTP Elite EL boiler to save fuel. Instead of heating its water to the same high temperature all winter, it uses a sensor outside your house to work out how hot the water really needs to be.

What happens, in order. The outdoor sensor measures the outside temperature. Using a curve set up by your installer, the control picks a heating water temperature to match. As an example from the factory settings, at an outdoor temperature of 5 °F the boiler supplies 190 °F water, and at 68 °F it supplies 95 °F water, with gradual steps between. Lowering the main heating set point moves the whole curve down. If the outside air climbs above the warm weather setting, 68 °F by default, the boiler is disabled altogether, because the house should not need heat. If the outdoor sensor fails and the sensor-failure function is on, the control ignores outdoor reset and uses the programmed temperature, and the display shows FOU.

What is normal. Radiators that feel only mildly warm on a mild day and hotter in a deep freeze, longer burner runs with lower flame, and no heating at all in warm weather even with the thermostat turned up.

Safe checks. Make sure nothing is covering the outdoor sensor, such as snow or a cover, and look at your thermostat setting. Do not change boiler settings yourself.

When to call a technician. If the house is cold in winter, the boiler fires on warm days, or FOU appears, book Aurora Star Tech and we will check the sensor and curve.

Key times at a glance

WhatHow long or how much
Warm weather shutoff68 F default
Min outdoor / max supply5 F / 190 F default
Max outdoor / min supply68 F / 95 F default

Applies to: EL-80, EL-110, EL-150, EL-220, EL-299, EL-399 (N/LP)

Error codes linked to this step

HTP code FOU

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the HTP boiler

What is the Outdoor reset and warm weather shutoff on a HTP boiler?

Outdoor reset is a clever way for the HTP Elite EL boiler to save fuel. Instead of heating its water to the same high temperature all winter, it uses a sensor outside your house to work out how hot the water really needs to be.

Is it normal for my HTP boiler to do this?

Radiators that feel only mildly warm on a mild day and hotter in a deep freeze, longer burner runs with lower flame, and no heating at all in warm weather even with the thermostat turned up.

Who can service my HTP boiler near me?

Aurora Star Tech Inc. repairs and services HTP boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.