Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Gree mini-split: Heating mode and anti-cold-air

Updated · by Aurora Star Tech Inc.

In Heat mode, a Gree Livo GEN4 mini-split pulls warmth from the outdoor air. This page explains when it turns on and off, and why the indoor fan holds back at first.

Homeowner with a ductless mini-split problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Gree mini-split works: Heating mode and anti-cold-air

What this is. In Heat mode, a Gree Livo GEN4 mini-split pulls warmth from the outdoor air. This page explains when it turns on and off, and why the indoor fan holds back at first.

What happens, in order. When the room is at or below your setting plus about 2 C, the reversing valve, the compressor and the outdoor fan start together. When the room reaches your setting plus about 3 C, the compressor stops, the outdoor fan runs on for 60 seconds and the indoor fan blows leftover heat on low for 60 seconds before stopping. You can pick any temperature from 61 to 86 F. To avoid cold drafts, the indoor fan follows an anti-cold-air routine. With the room below 75 F and the indoor coil at or below 104 F, the fan waits 2 minutes and then runs on low. If the coil passes 104 F sooner, the fan starts on low immediately, and after 1 minute on low it moves to your chosen speed. If the coil goes above 108 F during the wait or that minute, the fan goes straight to your speed. The same current-limiting steps used in cooling protect the unit.

What is normal. Up to two minutes of no airflow after starting, then a gentle breeze, and a short blow of warm air after the unit stops.

Safe checks. Confirm the remote is on Heat with a setting above room temperature, rinse the washable filters, keep the outdoor unit clear of snow and leaves, and check the breaker and remote batteries.

When to call a technician. Cold air continuing past ten minutes, frequent shutoffs or error codes. Aurora Star Tech can service your heat pump.

Key times at a glance

WhatHow long or how much
Residual heat blow60 s low
Outdoor fan run-on60 s
Fan wait2 min
Low speed run1 min
Coil thresholds104F / 108F

Applies to: Gree Livo GEN4 wall mini-split heat pumps 30k-36k

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Gree mini-split

What is the Heating mode and anti-cold-air on a Gree mini-split?

In Heat mode, a Gree Livo GEN4 mini-split pulls warmth from the outdoor air. This page explains when it turns on and off, and why the indoor fan holds back at first.

Is it normal for my Gree mini-split to do this?

Up to two minutes of no airflow after starting, then a gentle breeze, and a short blow of warm air after the unit stops.

Who can service my Gree mini-split near me?

Aurora Star Tech Inc. repairs and services Gree mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977