Gree mini-split: Compressor protections and lockouts
The compressor is the hardest-working and costliest part of your Gree Multi21+ system, so the outdoor unit watches over it closely. This page explains the protections that can slow it, stop it or hold it off until power is reset.
How the Gree mini-split works: Compressor protections and lockouts
What this is. The compressor is the hardest-working and costliest part of your Gree Multi21+ system, so the outdoor unit watches over it closely. This page explains the protections that can slow it, stop it or hold it off until power is reset.
What happens, in order. If the compressor coil or discharge temperature gets too high, the unit first adjusts the speed: it raises it when things are cool, holds or lowers it as things warm up, and stops the compressor if it becomes too hot. If the same protection appears six times in a row, the compressor will not restart until power is cut and restored; the count clears if the compressor has run for more than 7 minutes. If a high-pressure switch stays open for 3 seconds, the compressor stops, a signal goes to the indoor units and a power reset is needed to restart. A compressor overload device that trips will let the compressor restart by itself once it has been off over 3 minutes and has reset, but more than six trips (the count clears after 30 minutes of running) also blocks restart until power is cycled. After power-up, any indoor unit that has not communicated in 3 minutes is treated as not installed.
What is normal. A slower unit on a very hot day, a short wait before restarting, and an occasional protection that clears itself.
Safe checks. Keep the outdoor unit clear of leaves and give it airflow. You may switch the power off for a minute and back on once.
When to call. If the unit locks out again after a reset, a code stays on, or an indoor unit never responds, contact Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Repeat trips before lockout (discharge/overload coil) | 6 |
| Counter reset (those) | Compressor run over 7 min |
| Overload switch restart | Off over 3 min and switch reset |
| Overload switch lockout | More than 6 trips |
| Overload switch counter reset | Run over 30 min |
| High-pressure detect | 3 s open |
| Indoor unit detection | 3 min after power-up |
Applies to: Gree Multi21+ multi-zone heat pump outdoor units
Questions about the Gree mini-split
What is the Compressor protections and lockouts on a Gree mini-split?
The compressor is the hardest-working and costliest part of your Gree Multi21+ system, so the outdoor unit watches over it closely. This page explains the protections that can slow it, stop it or hold it off until power is reset.
Is it normal for my Gree mini-split to do this?
A slower unit on a very hot day, a short wait before restarting, and an occasional protection that clears itself.
Who can service my Gree mini-split near me?
Aurora Star Tech Inc. repairs and services Gree mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.