How the Gree mini-split works: Automatic defrost

What this is. In winter, the outdoor unit of your Gree Sapphire heat pump collects frost and must melt it off now and then. This page explains when that happens and what each step looks like.

What happens, in order. The unit considers defrost after 45 minutes of continuous heating or 90 minutes of total heating time, but only when the outdoor coil is colder than expected for the outdoor air temperature. Once those conditions are met, defrost begins 3 minutes later. The indoor fan and compressor stop, and 30 seconds later the outdoor fan stops. After another 30 seconds the reversing valve switches, and 30 seconds after that the compressor starts again and ramps up to defrost speed. Defrost lasts at most 7.5 minutes, or less if the outdoor air is 10 C (50 F) or warmer, then the compressor eases down, stops, and the valve switches back to heating. About 60 seconds later the compressor and outdoor fan restart, and the indoor fan resumes under its anti-cold-air rules.

What is normal. Steam from the outdoor unit, dripping water, a whoosh as the valve changes, and no warm air for several minutes. The remote shows H1 during defrost. This is not a fault, and the indoor panel does not show it.

Safe checks. Keep snow, ice and leaves away from the outdoor unit and leave space around it. Make sure the unit is in Heat mode and the filters are clean.

When to call a technician. Thick ice that stays for hours, defrost that repeats constantly, or a home that will not warm. Aurora Star Tech can help.

Key times at a glance

WhatHow long or how much
Heating run before defrost45 min continuous or 90 min accumulated
Delay after conditions met3 min
Defrost frequency85 Hz
Maximum defrost time7.5 min
Exit frequency46 Hz
Restart delay after valve switch60 s

Applies to: Gree Sapphire wall mini-split heat pumps

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Gree mini-split

What is the Automatic defrost on a Gree mini-split?

In winter, the outdoor unit of your Gree Sapphire heat pump collects frost and must melt it off now and then. This page explains when that happens and what each step looks like.

Is it normal for my Gree mini-split to do this?

Steam from the outdoor unit, dripping water, a whoosh as the valve changes, and no warm air for several minutes. The remote shows H1 during defrost. This is not a fault, and the indoor panel does not show it.

Who can service my Gree mini-split near me?

Aurora Star Tech Inc. repairs and services Gree mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977