Goodman-Amana-Daikin heat pump: Communicating heat pump heat, balance point and auxiliary heat

Updated · by Aurora Star Tech Inc.

A Goodman ComfortNet heat pump (ASZC, GSZC or DSZC with an AVPTC air handler) is smart about when to use outdoor heat and when to use electric heat. This page explains the idea of the balance point and how backup heat is added.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Goodman-Amana-Daikin heat pump works: Communicating heat pump heat, balance point and auxiliary heat

What this is. A Goodman ComfortNet heat pump (ASZC, GSZC or DSZC with an AVPTC air handler) is smart about when to use outdoor heat and when to use electric heat. This page explains the idea of the balance point and how backup heat is added.

What happens, in order. The control asks the heat pump for the outdoor air temperature. Above a limit called the balance point, the heat pump does the heating. Below it, the heat pump is locked out and only the electric heat runs, because at that temperature the heat pump is no longer efficient. Your installer sets this point, either in the CoolCloud HVAC app or with buttons on the board. When the heat pump runs, it starts at low stage, with a matching blower speed. If low stage cannot keep up, the blower and the heat pump both step up to high stage. If the house still needs more, auxiliary electric heat is added and the air handler picks the highest airflow needed. When the demand is met, the heat pump stops, the heaters are dropped and the blower continues until its off delay ends. The system can also start straight in high stage on a very cold day.

What is normal. Warm but not hot air from the heat pump, noticeably warmer air when electric heat joins, and changes in blower speed during a cycle.

Safe checks. Keep the filter clean, the outdoor unit clear of snow and debris, and the thermostat steady rather than making big jumps. Check the breaker.

When to call a technician. Cold air in heating mode, electric heat running all the time, or heating costs that suddenly rise. Aurora Star Tech can adjust the balance point to suit your home.

Applies to: Goodman ComfortNet ASZC / GSZC / DSZC heat pumps with AVPTC air handlers

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Goodman-Amana-Daikin heat pump

What is the Communicating heat pump heat, balance point and auxiliary heat on a Goodman-Amana-Daikin heat pump?

A Goodman ComfortNet heat pump (ASZC, GSZC or DSZC with an AVPTC air handler) is smart about when to use outdoor heat and when to use electric heat. This page explains the idea of the balance point and how backup heat is added.

Is it normal for my Goodman-Amana-Daikin heat pump to do this?

Warm but not hot air from the heat pump, noticeably warmer air when electric heat joins, and changes in blower speed during a cycle.

Who can service my Goodman-Amana-Daikin heat pump near me?

Aurora Star Tech Inc. repairs and services Goodman-Amana-Daikin heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.