Updated · by Aurora Star Tech Inc.

The GMVC95 or GMVC9 furnace from Goodman or Amana has a variable-speed blower, and it moves air for your air conditioner too. This page explains what the blower does during cooling and in fan-only mode.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Goodman-Amana-Daikin furnace works: Cooling and fan only

What this is. The GMVC95 or GMVC9 furnace from Goodman or Amana has a variable-speed blower, and it moves air for your air conditioner too. This page explains what the blower does during cooling and in fan-only mode.

What happens during cooling. When the thermostat calls for cooling, the control checks its safety circuits, and the outdoor fan and compressor start at the matching low or high speed. The blower starts at a cooling speed and a timing pattern called a ramp profile, which your installer chose when the system was set up. That profile decides how quickly the airflow builds, which is why the first minutes can feel gentle. If you have an electronic air cleaner, it turns on with the blower. When the thermostat is satisfied, the outdoor unit stops and the blower continues through a cool-down, with its length and airflow also set by the ramp profile, then the blower and air cleaner turn off.

Fan only. With the thermostat fan set to ON, there is a 5-second delay and then the blower runs steadily at a low speed, about 30 percent of the furnace's maximum airflow. It stops when the fan setting is turned off.

What is normal. Airflow that starts soft and builds, a blower that keeps running after the outdoor unit stops, and a low whisper of air in fan-only mode.

Safe checks. Confirm the thermostat is on Cool and set below room temperature, the filter is clean, vents are open, and the outdoor unit is clear of leaves and debris.

When to call a technician. Warm air during cooling, an outdoor unit that never starts, ice on the indoor line, or very weak airflow. Aurora Star Tech can service your furnace and air conditioner together.

Key times at a glance

WhatHow long or how much
Fan-only start delay5 s
Continuous fan airflow30 percent of max

Applies to: Goodman GMVC95 two-stage variable-speed furnaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Goodman-Amana-Daikin furnace

What is the Cooling and fan only on a Goodman-Amana-Daikin furnace?

The GMVC95 or GMVC9 furnace from Goodman or Amana has a variable-speed blower, and it moves air for your air conditioner too. This page explains what the blower does during cooling and in fan-only mode.

Is it normal for my Goodman-Amana-Daikin furnace to do this?

Airflow that starts soft and builds, a blower that keeps running after the outdoor unit stops, and a low whisper of air in fan-only mode.

Who can service my Goodman-Amana-Daikin furnace near me?

Aurora Star Tech Inc. repairs and services Goodman-Amana-Daikin furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.