Goodman-Amana-Daikin air conditioner: Cooling call with blower board delays
This page describes a cooling cycle for a Goodman R-410A air conditioner paired with an MBR or AR*F air handler. It explains why the indoor blower starts a few seconds after the outdoor unit and keeps running briefly afterwards.
How the Goodman-Amana-Daikin air conditioner works: Cooling call with blower board delays
What this is. This page describes a cooling cycle for a Goodman R-410A air conditioner paired with an MBR or AR*F air handler. It explains why the indoor blower starts a few seconds after the outdoor unit and keeps running briefly afterwards.
What happens, in order. When the room is warmer than your setting, the thermostat sends a signal to start the fan and cooling. The outdoor compressor and condenser fan start first. Seven seconds later, a small timer on the indoor blower board closes and the blower starts. When the room reaches your setting, the thermostat drops the call, the compressor and condenser fan stop, and the indoor blower keeps going for about 65 seconds, using up the cold left in the coil and sending it to the rooms.
What is normal. A moment of silence from the vents right after the system starts, and air continuing to blow for a minute or so after the outdoor unit stops. This short delay is designed to improve comfort and efficiency, and is not a fault.
Safe checks. Make sure the thermostat is on Cool and set below room temperature, the filter is clean, the vents are open, and the outdoor unit has clear space around it with no leaves or cottonwood fluff blocking it. Check the breaker once and try again.
When to call a technician. The outdoor unit hums but does not start, the blower never turns on, the air is warm, or ice forms on the lines. Aurora Star Tech services air conditioners across Vaughan, Toronto and the GTA.
Key times at a glance
| What | How long or how much |
|---|---|
| Blower on delay | 7 s |
| Blower off delay | 65 s |
Applies to: Goodman ASX / GSX / DSX air conditioners with MBR / AR*F air handlers
Questions about the Goodman-Amana-Daikin air conditioner
What is the Cooling call with blower board delays on a Goodman-Amana-Daikin air conditioner?
This page describes a cooling cycle for a Goodman R-410A air conditioner paired with an MBR or AR*F air handler. It explains why the indoor blower starts a few seconds after the outdoor unit and keeps running briefly afterwards.
Is it normal for my Goodman-Amana-Daikin air conditioner to do this?
A moment of silence from the vents right after the system starts, and air continuing to blow for a minute or so after the outdoor unit stops. This short delay is designed to improve comfort and efficiency, and is not a fault.
Who can service my Goodman-Amana-Daikin air conditioner near me?
Aurora Star Tech Inc. repairs and services Goodman-Amana-Daikin air conditioners in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.