Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

FlowMax boiler: Heating call with restart delay and pump overrun

Updated · by Aurora Star Tech Inc.

When your thermostat asks a FlowMax 90 or 120 boiler for heat, the boiler does more than simply fire and stop. It spaces out its starts and keeps the heating pump moving after the flame goes out, and this page explains why.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the FlowMax boiler works: Heating call with restart delay and pump overrun

What this is. When your thermostat asks a FlowMax 90 or 120 boiler for heat, the boiler does more than simply fire and stop. It spaces out its starts and keeps the heating pump moving after the flame goes out, and this page explains why.

What happens, in order. In WINTER or SUMMER/WINTER mode, a call from the thermostat makes the burner light. It then adjusts its flame up or down to reach the heating temperature you have set, rather than blasting at full power. When the call ends, the burner stops and the fan keeps running briefly to clear out the combustion chamber. The heating pump carries on for about three minutes as standard, moving the last of the hot water around the home, though an installer can set it to run permanently. A restart timer, normally also three minutes, then blocks a new heating start so the boiler cannot switch on and off in rapid bursts. There is also an optional water hammer protection that adds a very brief pause of about two seconds; whether it is on depends on how the installer set up your system. Setting changes only take effect after the boiler is switched off and on again.

What is normal. Pump noise after the flame is gone, a few minutes of no burner after a call ends, and gentle changes in flame size through the day.

Safe checks. Confirm the thermostat is set above room temperature and in heat mode, the front switch and breaker are on, and the pressure gauge looks normal. Please leave the settings alone.

When to call a technician. If the boiler shows E05, E01, E35, E16 or E42, cycles on and off constantly, or the home will not warm up. Aurora Star Tech can diagnose it.

Key times at a glance

WhatHow long or how much
Heating restart timer (param 6)00-90 steps of 5 s, default 36 = 180 s
Heating pump overrun (param 7)00-90 steps of 5 s, default 36 = 180 s
Pump mode during heating (param 4)00 standard 3 min overrun, 01 permanent
Water hammer prevention (param 5)00 off, 01 on (2 s)

Applies to: FLOWMAX-120

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the FlowMax boiler

What is the Heating call with restart delay and pump overrun on a FlowMax boiler?

When your thermostat asks a FlowMax 90 or 120 boiler for heat, the boiler does more than simply fire and stop. It spaces out its starts and keeps the heating pump moving after the flame goes out, and this page explains why.

Is it normal for my FlowMax boiler to do this?

Pump noise after the flame is gone, a few minutes of no burner after a call ends, and gentle changes in flame size through the day.

Who can service my FlowMax boiler near me?

Aurora Star Tech Inc. repairs and services FlowMax boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977