Carrier heat pump: Variable-speed unit: high pressure switch protection and lockout
If the refrigerant pressure in your Carrier Infinity variable-speed heat pump climbs too high, a safety switch stops the unit. It does not give up right away. It steps itself down and tries again, and this page explains how.
How the Carrier heat pump works: Variable-speed unit: high pressure switch protection and lockout
What this is. If the refrigerant pressure in your Carrier Infinity variable-speed heat pump climbs too high, a safety switch stops the unit. It does not give up right away. It steps itself down and tries again, and this page explains how.
What happens, in order. When the high pressure switch opens, code 31 appears. After 6 minutes, if heating or cooling is still wanted and the switch has closed again, a pressure equalizer valve opens for about 2.5 minutes to balance the system. The compressor and fan then restart one stage lower, and keep stepping down if the switch trips again. Once the unit has run 2 hours without further trips, the step-downs clear and it returns to full capacity. If it trips again at the lowest stage, the fault is raised to code 84, a high pressure lockout. From the top stages this takes five trips in a row, but from stage 1 just one.
What is normal. A single pause of about six minutes, then a restart that runs a bit quieter or slower, and a code 31 that fades by itself.
Safe checks. Replace a dirty filter, clean leaves and debris away from the outdoor coil, keep vents open and give the unit space. You may cycle the thermostat off and on once.
When to call. Code 84, a code 31 that returns, or weak heating or cooling means it is time to call Aurora Star Tech.
Key times at a glance
| What | How long or how much |
|---|---|
| Retry delay | 6 min |
| PEV equalize | 150 s |
| Reset of step-down | 2 h accumulated run without trips |
| HPS opens | 600 psig |
| HPS closes | 470 psig |
Applies to: Carrier Infinity 25VNA8 variable-speed heat pump and 24VNA9 variable-speed air conditioner
Error codes linked to this step
Carrier code 31Carrier code 84
Questions about the Carrier heat pump
What is the Variable-speed unit: high pressure switch protection and lockout on a Carrier heat pump?
If the refrigerant pressure in your Carrier Infinity variable-speed heat pump climbs too high, a safety switch stops the unit. It does not give up right away. It steps itself down and tries again, and this page explains how.
Is it normal for my Carrier heat pump to do this?
A single pause of about six minutes, then a restart that runs a bit quieter or slower, and a code 31 that fades by itself.
Who can service my Carrier heat pump near me?
Aurora Star Tech Inc. repairs and services Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.