Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier heat pump: Variable-speed heat pump: demand defrost with Auto interval

Updated · by Aurora Star Tech Inc.

Your Carrier Infinity variable-speed heat pump removes outdoor frost with a smart, self-adjusting defrost. This page explains how it decides, how long it runs and what you might see.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Carrier heat pump works: Variable-speed heat pump: demand defrost with Auto interval

What this is. Your Carrier Infinity variable-speed heat pump removes outdoor frost with a smart, self-adjusting defrost. This page explains how it decides, how long it runs and what you might see.

What happens, in order. The check interval is 30, 60 or 90 minutes, or Auto, which is the default with the Infinity Touch control. Auto picks the next interval from the last defrost: under 5 minutes gives 90, 5 to 7 gives 60, and over 7 gives 30. The board counts compressor run time, and as the interval nears it checks the coil. If the coil has been at or below 32 F for 4 minutes, it defrosts, otherwise the timer restarts. The first interval after power-up is 30 minutes. The compressor runs at a special defrost speed during the cycle. In outdoor air above 25 F, defrost ends once the coil passes 60 F, with a minimum of 1 minute. At 25 F or below, it ends when the coil passes 45 F, with a minimum of 2 minutes, or at 10 minutes maximum. The outdoor fan starts 10 seconds before the valve changes over, and backup heat stays on 15 seconds longer.

What is normal. Steam, dripping, a whoosh, and cooler indoor air for a few minutes.

Safe checks. Keep snow, ice and leaves away from the outdoor unit and make sure the thermostat is on Heat.

When to call. If ice builds up or heat is weak, call Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Interval options30 / 60 / 90 min or Auto
First interval30 min
Defrost demandcoil at or below 32 F for 4 min
Termination, OAT above 25 Fcoil above 60 F, min 1 min
Termination, OAT 25 F or lesscoil above 45 F, min 2 min
Maximum defrost10 min
Fan lead before reversing valve change10 s

Applies to: Carrier Infinity 25VNA8 variable-speed heat pump and 24VNA9 variable-speed air conditioner

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Carrier heat pump

What is the Variable-speed heat pump: demand defrost with Auto interval on a Carrier heat pump?

Your Carrier Infinity variable-speed heat pump removes outdoor frost with a smart, self-adjusting defrost. This page explains how it decides, how long it runs and what you might see.

Is it normal for my Carrier heat pump to do this?

Steam, dripping, a whoosh, and cooler indoor air for a few minutes.

Who can service my Carrier heat pump near me?

Aurora Star Tech Inc. repairs and services Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977