Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Carrier heat pump: Non-communicating heat pump: time/temperature defrost and Quiet Shift

Updated · by Aurora Star Tech Inc.

Frost builds on a heat pump's outdoor coil in cold, damp weather. Your Carrier Performance heat pump melts it away on a timer, checked against coil temperature. This page explains the cycle and the optional Quiet Shift feature.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Carrier heat pump works: Non-communicating heat pump: time/temperature defrost and Quiet Shift

What this is. Frost builds on a heat pump's outdoor coil in cold, damp weather. Your Carrier Performance heat pump melts it away on a timer, checked against coil temperature. This page explains the cycle and the optional Quiet Shift feature.

What happens, in order. A sensor on the coil closes at about 32 F and starts an interval timer, which the installer sets to 30, 60 or 90 minutes, or 120 on newer boards. If the coil warms and the sensor opens before the time is up, the timer resets. When the interval ends, the unit moves the valve to cooling position and stops the outdoor fan so hot refrigerant melts the frost. Defrost finishes when the coil reaches about 65 F, or after 10 minutes at most. With Quiet Shift on newer boards, the compressor switches off for 30 seconds going into defrost and again coming out, with the fan staying off an extra 40 seconds, which softens the noise of the changeover.

What is normal. Steam from the outdoor unit, dripping water, an outdoor fan that stops for a few minutes, a whoosh sound, and cooler indoor air for a short time.

Safe checks. Keep the outdoor unit clear of snow, ice and leaves. Confirm the thermostat is on Heat.

When to call. If thick ice builds up and stays, defrost seems to run constantly, or you have little heat, Aurora Star Tech can service your heat pump.

Key times at a glance

WhatHow long or how much
Defrost interval30 / 60 / 90 min (001/007); 30 / 60 / 90 / 120 min (003/008)
Defrost start temperatureabout 32 F coil
Defrost end temperatureabout 65 F coil
Maximum defrost length10 min
Quiet Shift compressor-off30 s in and 30 s out
Fan off after defrost (Quiet Shift)40 s
Forced defrost pin hold5 s

Applies to: Carrier / Bryant / Payne split heat pumps with HK32EA defrost control boards (Performance Series and Comfort Series)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Carrier heat pump

What is the Non-communicating heat pump: time/temperature defrost and Quiet Shift on a Carrier heat pump?

Frost builds on a heat pump's outdoor coil in cold, damp weather. Your Carrier Performance heat pump melts it away on a timer, checked against coil temperature. This page explains the cycle and the optional Quiet Shift feature.

Is it normal for my Carrier heat pump to do this?

Steam from the outdoor unit, dripping water, an outdoor fan that stops for a few minutes, a whoosh sound, and cooler indoor air for a short time.

Who can service my Carrier heat pump near me?

Aurora Star Tech Inc. repairs and services Carrier heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977