Carrier furnace: Furnace blower with outdoor A/C: cooling and continuous fan
In summer, your Carrier 58SB furnace is also the indoor fan for your central air conditioner. This page explains how the blower behaves with cooling and when you set the thermostat fan to run all the time.
How the Carrier furnace works: Furnace blower with outdoor A/C: cooling and continuous fan
What this is. In summer, your Carrier 58SB furnace is also the indoor fan for your central air conditioner. This page explains how the blower behaves with cooling and when you set the thermostat fan to run all the time.
What happens, in order. When the thermostat calls for cooling, it starts the outdoor air conditioner and signals the furnace blower to run on its cooling speed. When the house reaches temperature, the outdoor unit stops, but the blower keeps running for another 90 seconds to push the last of the cool air into your rooms. An installer can shorten that to 5 seconds. With the thermostat fan set to continuous, the blower runs on its fan speed all the time. If a heat call comes in, it pauses during igniter warm-up of about 17 seconds, the ignition, and the 25 second blower start delay, then returns on heat speed. When the fan setting is switched off, the blower runs about 5 seconds more.
What is normal. A blower that runs on for about a minute and a half after the air conditioner stops, and a different airflow sound in fan-only mode.
Safe checks. Replace a dirty filter, keep return grilles and supply vents open and clear the outdoor unit of leaves and debris. Check that the thermostat is in Cool mode, and use the Auto fan setting if you do not want constant airflow.
When to call. If the blower does not start with cooling, or the air is warm, Aurora Star Tech can help.
Key times at a glance
| What | How long or how much |
|---|---|
| Cooling blower-off delay | 90 s (5 s with J2 cut) |
| Blower-off after G opens | 5 s |
Applies to: Carrier 58SB0A / 58SB1A 80% single-stage gas furnace
Questions about the Carrier furnace
What is the Furnace blower with outdoor A/C: cooling and continuous fan on a Carrier furnace?
In summer, your Carrier 58SB furnace is also the indoor fan for your central air conditioner. This page explains how the blower behaves with cooling and when you set the thermostat fan to run all the time.
Is it normal for my Carrier furnace to do this?
A blower that runs on for about a minute and a half after the air conditioner stops, and a different airflow sound in fan-only mode.
Who can service my Carrier furnace near me?
Aurora Star Tech Inc. repairs and services Carrier furnaces in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.