How the Bosch tankless water heater works: Flow-activated hot water call

What this is. A Greentherm T9800/T9900 tankless water heater makes hot water only when you ask for it. This page follows what happens from the moment you open a hot tap to the moment you close it.

What happens, in order. When the water flowing through the heater reaches at least 0.45 gallons per minute, the unit decides someone wants hot water. If the installer has set a start delay, between 0 and 60 seconds, the burner waits for that time. The fan then starts, the igniter sparks, the gas valve opens, and a sensor confirms the flame. From there the gas valve adjusts the flame to hit the temperature you set, depending on how much water is flowing and how cold it is coming in. When flow falls to 0.35 gallons per minute, the burner stops. If solar preheated water arrives within about 1 F of the setpoint, the burner stays off and a solar indicator appears.

What is normal. A few seconds of cool water before the heat arrives, a fan noise and clicking at startup, and a burner that turns off if you run only a trickle.

Safe checks. Open the tap further, since a very low flow will not start the heater. Make sure the power and gas supply to the unit are on, and clear anything stored around the unit. If you ever smell gas, leave the house and call from outside.

When to call. Codes such as C1, C2, CF, EA or EC, or cold water at a normal flow, mean it is time to call Aurora Star Tech.

Key times at a glance

WhatHow long or how much
Activation flow0.45 GPM
Deactivation flow0.35 GPM
Burner start delay (A8)0-60 s

Applies to: Greentherm T9800 SE 160/199, T9900 SE 160/199

Error codes linked to this step

Bosch code C1Bosch code C2Bosch code CFBosch code EABosch code EC

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Bosch tankless water heater

What is the Flow-activated hot water call on a Bosch tankless water heater?

A Greentherm T9800/T9900 tankless water heater makes hot water only when you ask for it. This page follows what happens from the moment you open a hot tap to the moment you close it.

Is it normal for my Bosch tankless water heater to do this?

A few seconds of cool water before the heat arrives, a fan noise and clicking at startup, and a burner that turns off if you run only a trickle.

Who can service my Bosch tankless water heater near me?

Aurora Star Tech Inc. repairs and services Bosch tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.