Updated · by Aurora Star Tech Inc.

The first time a Bosch Greenstar 3A boiler is switched on, and again after it has been idle for a long stretch, it runs two short housekeeping routines. They look like odd behaviour, but they are normal.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

How the Bosch boiler works: First power-up purge and trap filling

What this is. The first time a Bosch Greenstar 3A boiler is switched on, and again after it has been idle for a long stretch, it runs two short housekeeping routines. They look like odd behaviour, but they are normal.

What happens, in order. After the ON/OFF switch is turned on for the very first time, the heating zone pump cycles on and off for about 4 minutes to push trapped air out of the system. On combi models the installer opens the automatic vent during this time and closes it afterwards. Separately, the boiler fills its condensate trap (the small water seal that carries away acidic water from the exhaust) when the burner has been idle for 28 days or more, when the unit is switched between summer and winter mode, or after the ON/OFF switch has been used. On the next call for heat or hot water, the boiler is held at low output for 15 minutes while the trap fills. During that time the display alternates a symbol with the supply temperature.

What is normal. Pump noise that starts and stops in the first few minutes, a boiler that seems to heat gently for a quarter of an hour, and a flashing symbol on the screen.

Safe checks. Give it the full 15 minutes before deciding it is slow. Check that the boiler is switched on, that the thermostat is calling for heat and that the breaker is on.

When to call. If you still have no heat after the 15 minutes, notice leaks, or see a fault code, call Aurora Star Tech.

Key times at a glance

WhatHow long or how much
First purgeabout 4 min
Trap filling run15 min at low output
Trap filling triggerburner idle 28 days

Applies to: Greenstar 3A series

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Questions about the Bosch boiler

What is the First power-up purge and trap filling on a Bosch boiler?

The first time a Bosch Greenstar 3A boiler is switched on, and again after it has been idle for a long stretch, it runs two short housekeeping routines. They look like odd behaviour, but they are normal.

Is it normal for my Bosch boiler to do this?

Pump noise that starts and stops in the first few minutes, a boiler that seems to heat gently for a quarter of an hour, and a flashing symbol on the screen.

Who can service my Bosch boiler near me?

Aurora Star Tech Inc. repairs and services Bosch boilers in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.