Trane Furnace: Upflow cased coil installation
Upflow cased coil installation on a Trane furnace: The cooling coil always sits downstream of the furnace airflow.
Applies to: Upflow furnaces with cased coil
How to fix upflow cased coil installation: step by step
- Attach the cased coil with the supplied standoffs and drill screws.
- Insert each standoff into the cabinet alignment hole, run the drill screws through the standoffs, and screw them into the furnace top flange.
- Use the clearance alignment holes near the bottom of the coil wrapper.
If the unit shows an error code, look it up: Trane Furnace codes
Models
UH1B040A9241AUH1B060A9361AUH1B080A9421BUH1C080A9601AUH1C100A9481AUH1D100A9601AUH1D120A9601A
More commissioning tips for furnace
Source: Trane AUH1B080A9421B installer's manual, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.