Trane Furnace: Resize remaining vent when a furnace is removed from a shared vent

Updated · by Aurora Star Tech Inc.

Resize remaining vent when a furnace is removed from a shared vent on a Trane furnace: Pulling a furnace out of a shared vent leaves the other gas appliances on a vent that was sized for more input than they put out. I have found plenty of water heaters sitting on a leftover oversized flue, spilling and rusting at the draft hood. The fix is to size the vent for what is actually left, using the code tables.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Furnace replaced in a common vent system

Common causes of resize remaining vent when a furnace is removed from a shared vent

  • Vent system sized for the removed furnace plus other appliances
  • Weak draft or spillage on the remaining appliances
  • Condensation in an oversized vent after the furnace heat is gone

How to fix resize remaining vent when a furnace is removed from a shared vent: step by step

  1. Find the Btu/hr input of all remaining appliances on the vent.
  2. Measure the diameter, rise and lateral of the existing vent, and count the number and type of bends.
  3. Use the tables in the current National Fuel Gas Code (ANSI Z223.1 / CAN/CGA B149.1) or Exhibit J of ANSI Z21.47 / CAN/CGA-2.3 to check or resize the vent.
  4. Check draft at the remaining appliance with it running.
  5. Let a licensed gas fitter correct the vent if it is oversized.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

Source: Trane AUH1B080A9421B installer's manual, p. 18. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.