Trane Furnace: Horizontal installation support and drain
Horizontal installation support and drain on a Trane furnace: When you lay a furnace on its side, the coil and the furnace both need real support and a way to get rid of water. People forget the coil drain, and the first summer there is a ceiling stain. The rules below are for the UH1 upflow converted to horizontal and the DH1 downflow in horizontal. Take your time on support, because a sagging cabinet can bind the doors and put stress on the drain connections.
Applies to: UH1 upflow converted to horizontal and DH1 downflow in horizontal position
Common causes of horizontal installation support and drain
- Upflow UH1 being converted to a horizontal install
- DH1 downflow furnace set in the horizontal position
- A horizontal evaporator coil or 95% furnace sitting over a finished space
- New install where the cased coil needs stabilizing
How to fix horizontal installation support and drain: step by step
- Install an auxiliary drain pan under a horizontal evaporator coil or 95% furnace. Run the auxiliary drain to a separate line (no trap needed)
- Fit the three brackets included with downflow furnaces to stabilise the furnace and TXC cased coil, using the rear coil case screws and four bracket screws
- Place the 2/4TXC coil downstream of the furnace. The coil apex may point toward or away from the furnace
- Support the furnace at both ends and in the middle
- Raise the furnace at least 6 in so the condensate drain can exit the cabinet
- Check that the unit has the slope required by the installer's guide so condensate runs the right way
If the unit shows an error code, look it up: Trane Furnace codes
Models
DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601
Source: Trane installer's guide 18-CD29D1-11, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.