Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane Furnace: Duct connection and return air

Updated · by Aurora Star Tech Inc.

Duct connection and return air on a Trane furnace: Duct layout and return air requirements for the furnace.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: UH1/DH1 furnaces

How to fix duct connection and return air: step by step

  1. Size ducts per ACCA Manual D and install them per NFPA 90.
  2. If a cooling coil is used, install the furnace upstream of the coil or in parallel with it. Parallel dampers must stop chilled air entering the furnace.
  3. Use flexible connectors on supply and return to reduce vibration.
  4. Route returns away from the living area where possible to cut noise.
  5. If supply ducts carry air outside the furnace room, seal the return to the furnace and terminate it outside that space.
  6. Make sure the return duct includes provision for return air filters.
  7. On side return upflow installs, remove the insulation around the opening in the blower compartment.
  8. Cut the return opening using the locating notches on the side panels and the outline drawing dimensions.
  9. If a 3/4 in flange is needed, extend the cut as shown, cut corners diagonally and bend outward.
  10. If no flange is needed and a filter frame is used, cut along the knockout guidelines.
  11. Connect supply and return ducts to the furnace using the outline drawing sizes and locations.
  12. When replacing a furnace, clean out old ductwork, cover registers with thin cloths and run the fan for 10 minutes. Remove the cloths before starting the furnace.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

Models

DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601

Source: Trane installer's guide 18-CD29D1-11, pp. 9-11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Furnace Repair

647-657-2977