Trane Furnace: Downflow furnace on combustible floor (subbase)

Updated · by Aurora Star Tech Inc.

Downflow furnace on combustible floor (subbase) on a Trane furnace: DH1 downflow on a combustible floor. Can't sit it right on carpet, tile or any combustible flooring. Wood flooring is the exception. Use the subbase.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: DH1 downflow furnaces

Common causes of downflow furnace on combustible floor (subbase)

  • Not a fault. Floor protection requirement for a downflow install.

How to fix downflow furnace on combustible floor (subbase): step by step

  1. Put subbase BAYBASE-205 between the furnace and combustible flooring on vertical downflow installs.
  2. Downflow vertical with a cased coil? No subbase needed.
  3. Cut the floor opening to the dimensions in Table 1.
  4. Check the opening is square and clear of joists or wiring.
  5. Seat the furnace on the subbase and confirm no gaps around it.
  6. Check clearances to combustibles on the rating plate before leaving.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Trane Furnace codes

Models

DH1B040A9241DH1B065A9421DH1C085A9481DH1D110A9601UC1B060CUH1C080A9601UH1C100A9481UH1D100A9601UH1D120A9601

Source: Trane installer's guide 18-CD29D1-11, p. 8. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.